Emailrongbaipump@foxmail.com
SP30-1A Industrial Syringe Pump, Compact, OEM dispensing pump
1 Channel
All components are made of safety-certified components. They are not medical equipment and are not subject to food and drug management regulations.
The SP30-1A is a compact OEM syringe pump used to transfer precision fluids. It is controlled by a computer or microprocessor to automatically complete pipetting, diluting and dispensing functions.
Travel control accuracy: <=1% (full travel)
Travel control accuracy: < ±5%0> (full travel)
    Features & Benefits
    Brochure
    Video
    Related Products
Technical Specifications
Accuracy ≤1.0 % (syringe ≥1 mL)
Precision CV≤0.05% at full stroke (with syringe ≥ 500 uL )
Wetted material Borosilicate glass,PTFE,PFA,CTFE,ETFE,UHMW-PE
Dimension (L x W x H) 142.69mm*44.4mm*127mm
Power supply DC 24V,1.5A (peak)
Syringe and Drive
Syringe fitting 1/4″-28 thread
Syringe 50uL, 100uL, 250uL, 500uL, 1mL, 2.5mL, 5mL
Syringe material Borosilicate glass,stainless steel plunger with PTFE coating, PTFE or UHMW-PE plunger tip
Resolution (standard mode) 3000 steps with 0.01mm in 1 step
Travel 30mm
Time for full stroke 1.26s-1200s
Drive system Ball screw drive
Valve & Valve Drive
Turn Time ≤250ms between adjacent ports
Valve options Standard: 3-port valve; optional: 3-port distribution valve, 4-port valve, T-valve, through valve or valve free
Max pressure 0.68MPA
Fitting 1/4″-28 thread
Communication
Interface RS485, RS232, external control input and output
Protocol Data terminal,OEM protocol (serial)
Baud rate 9600bps or 38400bps
Format Data bit: 8; parity: none; stop bit: 1; half duplex (RS232/485)
Firmware
Topology group Up to 15 pumps in one group, support group control and individually addressed
Homing Algorithm Plunger home position is identified by motor stall, which will reduce the dead volume of the system
Halt function "h " command is used to halt execution of the command string during plunger movement. To resume execution with "R" or "r" command
Programmable parameter Programmable ramps, cut-off velocity, plunger speeds, backlash compensation,programmable work-flow command set , delays and loops, terminate moves, diagnostics, absolute and relative positions
Environmental
Operating temperature Recommended: 15℃-40℃ ,use low temperature syringe for low temperature application
Operating Humidity <80% RH, no condensation
Storage temperature  -20℃-65℃
Storage Humidity <80% RH, no condensation
SP30-1A Industrial Syringe Pump, Compact, OEM dispensing pump